> Here are details and pics given by Vincent Pierré - Terranergie :  
> Bureau d'Etude : Thermique - Energétique - Matériaux - Permaculture  
> - Transition énergétique. terranergie at aliceadsl.fr
>
> The prefab panels are made of Agepan DWD16
> rigidified by wood 40X40mm (1.57") glued and nailed
>
> Panels:
> 2500X1250X400mm
> 98.4"x49.2x15.7"
>
> Bales
> 490X380X1200mm
> 19.2x14.9x47.2"
> Density (probably dry) 135kg/m3
>
> Primary wood structure
> KLH-board 150mm (5.9") cross laminated timber-box
>
> Did someone from the French strawbale community act as a consultant  
> for the straw bale aspects?
> Vincent Pierré, member of our French SB Network did the design,  
> defined the size, density of bales to use, tested the filling of the  
> panels etc.
>
> Did the architect in the video have previous experience with straw  
> bale building?
> No.
>
> What are the blue pastic-buttons in the wall (for measurement?)
> They are télescope SFS INTEC that hold the bales against the wood  
> structure without creating a thermal bridge.
>
> what about the load transfer of the modules, are they just fixed on  
> the KLH-board (cross laminated timber-box)?
> The loads descend through the uprights on the exterior that form I  
> beams and are supported by the foundation.
>
> Do you know, did they only cut the strings of the bales or did they  
> fill in loose straw as well to avoid gaps?
> They checked if the cutting of the strings sufficed for filling the  
> holes (and it did)
> The bales are compressed to achieve 135kg/m3 and are 2cm (0.78")  
> shorter than the space to fill. After cutting the strings there are  
> no more empty spots.
>
> And a little correction : Acording to Passiv Haus standard (15 kWh/ 
> m2) this social housing should NOT exceed 130€ per year for heating,  
> cooling, ventilation and warm water costs for an appartment of 90m²  
> (about 900ft²).
>
> Bye,
> André - the sky is the limit - de Bouter
> ____________________________________________________
>   European strawbale building discussion list
>
> Send all messages to:
> Strawbale at amper.ped.muni.cz
>
> Archives, subscription options, etc:
> http://amper.ped.muni.cz/mailman/listinfo/strawbale
> ____________________________________________________
>
>
>

-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://amper.ped.muni.cz/pipermail/strawbale/attachments/20130518/0d242e78/attachment.html>


More information about the Strawbale mailing list