I know, limit is in our immagination, but some photos would help...😊
Thank you André to share informations.
stefano
www.laboa.org
> Date: Sat, 18 May 2013 12:29:21 +0200
> From: contact at lamaisonenpaille.com
> To: strawbale at amper.ped.muni.cz
> Subject: [Strawbale] 7story SB buildings in France - details
>
> Here are details and pics given by Vincent Pierré - Terranergie : Bureau
> d'Etude : Thermique - Energétique - Matériaux - Permaculture -
> Transition énergétique. terranergie at aliceadsl.fr
>
> The prefab panels are made of Agepan DWD16
> rigidified by wood 40X40mm (1.57") glued and nailed
>
> Panels:
> 2500X1250X400mm
> 98.4"x49.2x15.7"
>
> Bales
> 490X380X1200mm
> 19.2x14.9x47.2"
> Density (probably dry) 135kg/m3
>
> Primary wood structure
> KLH-board 150mm (5.9") cross laminated timber-box
>
> Did someone from the French strawbale community act as a consultant for
> the straw bale aspects?
> Vincent Pierré, member of our French SB Network did the design, defined
> the size, density of bales to use, tested the filling of the panels etc.
>
> Did the architect in the video have previous experience with straw bale
> building?
> No.
>
> What are the blue pastic-buttons in the wall (for measurement?)
> They are télescope SFS INTEC that hold the bales against the wood
> structure without creating a thermal bridge.
>
> what about the load transfer of the modules, are they just fixed on the
> KLH-board (cross laminated timber-box)?
> The loads descend through the uprights on the exterior that form I beams
> and are supported by the foundation.
>
> Do you know, did they only cut the strings of the bales or did they fill
> in loose straw as well to avoid gaps?
> They checked if the cutting of the strings sufficed for filling the
> holes (and it did)
> The bales are compressed to achieve 135kg/m3 and are 2cm (0.78") shorter
> than the space to fill. After cutting the strings there are no more
> empty spots.
>
> And a little correction : Acording to Passiv Haus standard (15 kWh/m2)
> this social housing should NOT exceed 130€ per year for heating,
> cooling, ventilation and warm water costs for an appartment of 90m²
> (about 900ft²).
>
> Bye,
> André - the sky is the limit - de Bouter
> ____________________________________________________
> European strawbale building discussion list
>
> Send all messages to:
> Strawbale at amper.ped.muni.cz
>
> Archives, subscription options, etc:
> http://amper.ped.muni.cz/mailman/listinfo/strawbale
> ____________________________________________________
>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://amper.ped.muni.cz/pipermail/strawbale/attachments/20130518/a1e5e3b7/attachment.html>
More information about the Strawbale
mailing list