| In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91
# [TEST] GE 7024
# [MANUFAC] GE Lighting Systems - Hendersonville NC USA
# [LUMCAT] (not specific to a single catalog number)
# [LUMINAIRE] GE FILTRGARD
# [LAMP] HPS 70-150
# [OTHER] Distribution: SC 1.5
# [MORE] Socket Pos: FIXED
# [MORE] Comments: SM GLOB&GD DDR -
# [MORE] Revision No: 0 Rev Date: 810821 Test Date: 80090202
# [MORE] Reflector: - Refractor: -
# TILT=NONE
# Bulbs: 1, 10000 lm each
# Number of measured angles: 37 vertical, 1 horizontal ones
# Photometric type: 1, Units type: 1
# Luminous opening diameter (and height?): 1.500 ( 0.000 )
# Ballast factor: 1, Input power: 0 W
# Source file: ies/ge7024.ies
# Luminaire flux = 6035 lm,
# 60.3 % of the bulb flux
# between 75 and 90: 1.2 % of the luminaire flux
# - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above: max 6.0 cd/1000lm , 0.5 % of the luminaire flux
# 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux
# CutOff Type: Full_CutOff
# 62.5 deg to <67.5 deg: max 52 cd/1000lm,
# 67.5 deg to <72.5 deg: max 26 cd/1000lm,
# maximum spec. lum. intensity 217 cd/1000lm
# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):
0.0 190
5.0 188
10.0 194
15.0 203
20.0 217
25.0 213
30.0 199
35.0 188
40.0 177
45.0 162
50.0 142
55.0 131
60.0 103
65.0 52.0
70.0 26.0
75.0 12.0
80.0 6.0
85.0 2.0
90.0 0.0
95.0 0.0
100.0 0.0
105.0 0.0
110.0 0.0
115.0 0.0
120.0 0.0
125.0 0.0
130.0 0.0
135.0 0.0
140.0 0.0
145.0 0.0
150.0 0.0
155.0 0.0
160.0 0.0
165.0 0.0
170.0 0.0
175.0 0.0
180.0 0.0