AW: [Strawbale] fire
Hannes Hohensinner
hh at grat...
Wed Apr 2 11:12:21 CEST 2003
Dear Rikki!
We tested a strawbale wall (Wooden frame construction with straw bales) with
inside clay plaster and outside lime plaster. The result was 90 minutes fire
resistance. Have a look at www.grat.at and go to "Publikationen". You can
find the test certificate under "Wandsystem aus Nachwachsenden Rohstoffen",
go to "Anhang" for download as pdf file. It is in German, but the
characteristics of the wall are shown in some diagramms.
best regards
Hannes
Dipl. Ing. Hannes Hohensinner
Gruppe Angepasste Technologie (GrAT)/TU Wien
Wiedner Hauptstrasse 8-10
A-1040 Wien
www.grat.tuwien.ac.at
-----Ursprüngliche Nachricht-----
Von: strawbale-admin at amper....muni.cz
[mailto:strawbale-admin at amper....muni.cz]Im Auftrag von rikki nitzkin
Gesendet: Montag, 31. März 2003 13:12
An: strawbale at amper....muni.cz
Betreff: [Strawbale] fire
Can someone please direct to where I can find info. on the resistance of
earth plastered SB wall to fire?
love , RIKKI
"you´ll end terrorism when there´s no longer anything for anybody to get
pissed off about."