In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91 # [TEST] LSI 10923 # [DATE] 08/12/92 # [MANUFAC] RUUD LIGHTING # [LUMCAT] RT215MH # [LUMINAIRE] REGRESSED FRESNEL # [LAMP] 70W MH # TILT=NONE # Bulbs: 1, 5600 lm each # Number of measured angles: 19 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous openig width, length and height: 0.420 0.420 0.000 # Ballast factor: 1, Input power: 95 W # Source file: rt215mh.ies # Luminaire flux = 2441 lm, # 43.6 % of the bulb flux # between 75 and 90: 0.1 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux # 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 20 cd/1000lm, # 67.5 deg to <72.5 deg: max 14 cd/1000lm, # maximum spec. lum. intensity 524 cd/1000lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 524 5.0 407 10.0 286 15.0 211 20.0 187 25.0 203 30.0 182 35.0 162 40.0 148 45.0 95.0 50.0 69.1 55.0 49.5 60.0 31.3 65.0 19.8 70.0 13.8 75.0 2.3 80.0 0.0 85.0 0.0 90.0 0.0 # IESNA91 # [TEST] LSI 10923 # [DATE] 08/12/92 # [MANUFAC] RUUD LIGHTING # [LUMCAT] RT215MH # [LUMINAIRE] REGRESSED FRESNEL # [LAMP] 70W MH # TILT=NONE # Bulbs: 1, 5600 lm each # Number of measured angles: 19 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous openig width, length and height: 0.420 0.420 0.000 # Ballast factor: 1, Input power: 95 W # Source file: rt215mh.ies # Luminaire flux = 2441 lm, # 43.6 % of the bulb flux # between 75 and 90: 0.1 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 0.0 cd / 1000 lm , 0.0 % of the luminaire flux # 90deg and above: max 0.0 cd / 1000 lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 20 cd / 1000 lm, # 67.5 deg to < 76 deg: max 14 cd / 1000 lm, # maximum spec. lum. intensity 524 cd / 1000 lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 524 5.0 407 10.0 286 15.0 211 20.0 187 25.0 203 30.0 182 35.0 162 40.0 148 45.0 95.0 50.0 69.1 55.0 49.5 60.0 31.3 65.0 19.8 70.0 13.8 75.0 2.3 80.0 0.0 85.0 0.0 90.0 0.0