In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91 # [TEST] LSI 7772 # [DATE] 04/07/89 # [MANUFAC] RUUD LIGHTING # [LUMCAT] RT19A21 # [LUMINAIRE] CLEAR REFLECTOR # [LAMP] 150W A21 # TILT=NONE # Bulbs: 1, 2830 lm each # Number of measured angles: 19 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous openig width, length and height: 0.480 0.480 0.000 # Ballast factor: 1, Input power: 150 W # Source file: rt19a21.ies # Luminaire flux = 1959 lm, # 69.2 % of the bulb flux # between 75 and 90: 0.0 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 0.4 cd/1000lm , 0.0 % of the luminaire flux # 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 4 cd/1000lm, # 67.5 deg to <72.5 deg: max 1 cd/1000lm, # maximum spec. lum. intensity 300 cd/1000lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 273 5.0 275 10.0 279 15.0 274 20.0 278 25.0 293 30.0 300 35.0 291 40.0 264 45.0 222 50.0 166 55.0 104 60.0 42.8 65.0 3.5 70.0 0.7 75.0 0.4 80.0 0.4 85.0 0.0 90.0 0.0 # IESNA91 # [TEST] LSI 7772 # [DATE] 04/07/89 # [MANUFAC] RUUD LIGHTING # [LUMCAT] RT19A21 # [LUMINAIRE] CLEAR REFLECTOR # [LAMP] 150W A21 # TILT=NONE # Bulbs: 1, 2830 lm each # Number of measured angles: 19 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous openig width, length and height: 0.480 0.480 0.000 # Ballast factor: 1, Input power: 150 W # Source file: rt19a21.ies # Luminaire flux = 1959 lm, # 69.2 % of the bulb flux # between 75 and 90: 0.0 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 0.4 cd / 1000 lm , 0.0 % of the luminaire flux # 90deg and above: max 0.0 cd / 1000 lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 4 cd / 1000 lm, # 67.5 deg to < 76 deg: max 1 cd / 1000 lm, # maximum spec. lum. intensity 300 cd / 1000 lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 273 5.0 275 10.0 279 15.0 274 20.0 278 25.0 293 30.0 300 35.0 291 40.0 264 45.0 222 50.0 166 55.0 104 60.0 42.8 65.0 3.5 70.0 0.7 75.0 0.4 80.0 0.4 85.0 0.0 90.0 0.0