Illuminance plots of rt19a19

(as computed by ies2tab from that IES photometry file)

spacing 5 plot single luminaire plot
In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). The right plot is for a single luminaire, unrotated.

illuminance scale

Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.

ies2tab text output:

   
       
# IESNA91
# [TEST] LSI 8421
# [DATE] 04/06/89
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] RT19A19
# [LUMINAIRE] CLEAR REFLECTOR
# [LAMP] 100W A19
# TILT=NONE
# Bulbs: 1,   1750 lm each
# Number of measured angles:  19 vertical,   1 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous openig width, length and height:   0.480   0.480   0.000
# Ballast factor: 1,  Input power:  100 W


# Source file: rt19a19.ies
# Luminaire flux =  1093 lm,
#                   62.4 % of the bulb flux
# between 75 and 90:  0.2 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max   1.7 cd/1000lm ,  0.1 % of the luminaire flux
# 90deg and above:  max   0.0 cd/1000lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max     2 cd/1000lm,
# 67.5 deg to <72.5 deg:   max     2 cd/1000lm,
# maximum spec. lum. intensity   763 cd/1000lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

  0.0   763
  5.0   729
 10.0   671
 15.0   585
 20.0   486
 25.0   394
 30.0   305
 35.0   213
 40.0   134
 45.0  78.9
 50.0  38.9
 55.0  13.1
 60.0   2.9
 65.0   2.3
 70.0   1.7
 75.0   1.7
 80.0   1.7
 85.0   1.1
 90.0   0.0

# IESNA91
# [TEST] LSI 8421
# [DATE] 04/06/89
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] RT19A19
# [LUMINAIRE] CLEAR REFLECTOR
# [LAMP] 100W A19
# TILT=NONE
# Bulbs: 1,   1750 lm each
# Number of measured angles:  19 vertical,   1 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous openig width, length and height:   0.480   0.480   0.000
# Ballast factor: 1,  Input power:  100 W


# Source file: rt19a19.ies
# Luminaire flux =  1093 lm,
#                   62.4 % of the bulb flux
# between 75 and 90:  0.2 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max   1.7 cd / 1000 lm ,  0.1 % of the luminaire flux
# 90deg and above:  max   0.0 cd / 1000 lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max     2 cd / 1000 lm,
# 67.5 deg to < 76  deg:   max     2 cd / 1000 lm,
# maximum spec. lum. intensity   763 cd / 1000 lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

  0.0   763
  5.0   729
 10.0   671
 15.0   585
 20.0   486
 25.0   394
 30.0   305
 35.0   213
 40.0   134
 45.0  78.9
 50.0  38.9
 55.0  13.1
 60.0   2.9
 65.0   2.3
 70.0   1.7
 75.0   1.7
 80.0   1.7
 85.0   1.1
 90.0   0.0