Illuminance plots of rt18mh

(as computed by ies2tab from that IES photometry file)

spacing 5 plot single luminaire plot
In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). The right plot is for a single luminaire, unrotated.

illuminance scale

Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.

ies2tab text output:

   
       
# IESNA91
# [TEST] LSI 10930
# [DATE] 08/18/92
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] RT18MH
# [LUMINAIRE] BAFFLE W/REFLECTOR
# [LAMP] 70 WATT MH / COATED
# TILT=NONE
# Bulbs: 1,   5600 lm each
# Number of measured angles:  37 vertical,   1 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous opening diameter (and height?):   0.500  (   0.000 )
# Ballast factor: 1,  Input power:   95 W


# Source file: rt18mh.ies
# Luminaire flux =  2655 lm,
#                   47.4 % of the bulb flux
# between 75 and 90:  0.0 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max   0.0 cd/1000lm ,  0.0 % of the luminaire flux
# 90deg and above:  max   0.0 cd/1000lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max    18 cd/1000lm,
# 67.5 deg to <72.5 deg:   max     9 cd/1000lm,
# maximum spec. lum. intensity   284 cd/1000lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

  0.0   192
  2.5   190
  5.0   187
  7.5   185
 10.0   186
 12.5   188
 15.0   190
 17.5   193
 20.0   199
 22.5   207
 25.0   231
 27.5   272
 30.0   284
 32.5   272
 35.0   247
 37.5   212
 40.0   174
 42.5   137
 45.0   108
 47.5  85.9
 50.0  69.3
 52.5  55.4
 55.0  42.7
 57.5  33.0
 60.0  24.8
 62.5  18.2
 65.0  12.9
 67.5   8.6
 70.0   5.2
 72.5   2.7
 75.0   1.1
 77.5   0.2
 80.0   0.0
 82.5   0.0
 85.0   0.0
 87.5   0.0
 90.0   0.0

# IESNA91
# [TEST] LSI 10930
# [DATE] 08/18/92
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] RT18MH
# [LUMINAIRE] BAFFLE W/REFLECTOR
# [LAMP] 70 WATT MH / COATED
# TILT=NONE
# Bulbs: 1,   5600 lm each
# Number of measured angles:  37 vertical,   1 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous opening diameter (and height?):   0.500  (   0.000 )
# Ballast factor: 1,  Input power:   95 W


# Source file: rt18mh.ies
# Luminaire flux =  2655 lm,
#                   47.4 % of the bulb flux
# between 75 and 90:  0.0 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max   0.0 cd / 1000 lm ,  0.0 % of the luminaire flux
# 90deg and above:  max   0.0 cd / 1000 lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max    18 cd / 1000 lm,
# 67.5 deg to < 76  deg:   max     9 cd / 1000 lm,
# maximum spec. lum. intensity   284 cd / 1000 lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

  0.0   192
  2.5   190
  5.0   187
  7.5   185
 10.0   186
 12.5   188
 15.0   190
 17.5   193
 20.0   199
 22.5   207
 25.0   231
 27.5   272
 30.0   284
 32.5   272
 35.0   247
 37.5   212
 40.0   174
 42.5   137
 45.0   108
 47.5  85.9
 50.0  69.3
 52.5  55.4
 55.0  42.7
 57.5  33.0
 60.0  24.8
 62.5  18.2
 65.0  12.9
 67.5   8.6
 70.0   5.2
 72.5   2.7
 75.0   1.1
 77.5   0.2
 80.0   0.0
 82.5   0.0
 85.0   0.0
 87.5   0.0
 90.0   0.0