Illuminance plots of rt18f-32

(as computed by ies2tab from that IES photometry file)

spacing 5 plot single luminaire plot
In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). The right plot is for a single luminaire, unrotated.

illuminance scale

Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.

ies2tab text output:

   
       
# IESNA91
# [TEST] LSI 12229
# [DATE] 09/12/95
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] RT18F-32
# [LUMINAIRE] BAFFLE W/REFLECTOR
# [LAMP] 32W FL
# TILT=NONE
# Bulbs: 1,   2400 lm each
# Number of measured angles:  37 vertical,   1 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous opening diameter (and height?):   0.470  (   0.000 )
# Ballast factor: 1,  Input power:   32 W


# Source file: rt18f-32.ies
# Luminaire flux =  1002 lm,
#                   41.8 % of the bulb flux
# between 75 and 90:  0.2 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max   0.4 cd/1000lm ,  0.1 % of the luminaire flux
# 90deg and above:  max   0.0 cd/1000lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max    33 cd/1000lm,
# 67.5 deg to <72.5 deg:   max    19 cd/1000lm,
# maximum spec. lum. intensity   212 cd/1000lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

  0.0   193
  2.5   194
  5.0   198
  7.5   203
 10.0   210
 12.5   212
 15.0   212
 17.5   208
 20.0   201
 22.5   193
 25.0   185
 27.5   178
 30.0   170
 32.5   161
 35.0   150
 37.5   138
 40.0   125
 42.5   112
 45.0  99.6
 47.5  88.8
 50.0  77.9
 52.5  67.9
 55.0  58.8
 57.5  49.6
 60.0  41.3
 62.5  33.3
 65.0  25.8
 67.5  19.2
 70.0  12.9
 72.5   7.1
 75.0   3.3
 77.5   0.8
 80.0   0.4
 82.5   0.4
 85.0   0.4
 87.5   0.0
 90.0   0.0

# IESNA91
# [TEST] LSI 12229
# [DATE] 09/12/95
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] RT18F-32
# [LUMINAIRE] BAFFLE W/REFLECTOR
# [LAMP] 32W FL
# TILT=NONE
# Bulbs: 1,   2400 lm each
# Number of measured angles:  37 vertical,   1 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous opening diameter (and height?):   0.470  (   0.000 )
# Ballast factor: 1,  Input power:   32 W


# Source file: rt18f-32.ies
# Luminaire flux =  1002 lm,
#                   41.8 % of the bulb flux
# between 75 and 90:  0.2 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max   0.4 cd / 1000 lm ,  0.1 % of the luminaire flux
# 90deg and above:  max   0.0 cd / 1000 lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max    33 cd / 1000 lm,
# 67.5 deg to < 76  deg:   max    19 cd / 1000 lm,
# maximum spec. lum. intensity   212 cd / 1000 lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

  0.0   193
  2.5   194
  5.0   198
  7.5   203
 10.0   210
 12.5   212
 15.0   212
 17.5   208
 20.0   201
 22.5   193
 25.0   185
 27.5   178
 30.0   170
 32.5   161
 35.0   150
 37.5   138
 40.0   125
 42.5   112
 45.0  99.6
 47.5  88.8
 50.0  77.9
 52.5  67.9
 55.0  58.8
 57.5  49.6
 60.0  41.3
 62.5  33.3
 65.0  25.8
 67.5  19.2
 70.0  12.9
 72.5   7.1
 75.0   3.3
 77.5   0.8
 80.0   0.4
 82.5   0.4
 85.0   0.4
 87.5   0.0
 90.0   0.0