In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91 # [TEST] LSI 12232 # [DATE] 09/11/95 # [MANUFAC] RUUD LIGHTING # [LUMCAT] RT18F-26 # [LUMINAIRE] BAFFLE W/REFLECTOR # [LAMP] 26W FL # TILT=NONE # Bulbs: 1, 1800 lm each # Number of measured angles: 37 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous opening diameter (and height?): 0.470 ( 0.000 ) # Ballast factor: 1, Input power: 27 W # Source file: rt18f-26.ies # Luminaire flux = 860 lm, # 47.8 % of the bulb flux # between 75 and 90: 0.1 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 0.6 cd/1000lm , 0.1 % of the luminaire flux # 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 15 cd/1000lm, # 67.5 deg to <72.5 deg: max 2 cd/1000lm, # maximum spec. lum. intensity 268 cd/1000lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 252 2.5 253 5.0 257 7.5 263 10.0 266 12.5 268 15.0 268 17.5 263 20.0 254 22.5 244 25.0 234 27.5 223 30.0 212 32.5 199 35.0 186 37.5 171 40.0 154 42.5 137 45.0 121 47.5 105 50.0 88.9 52.5 73.9 55.0 57.8 57.5 42.2 60.0 27.8 62.5 15.0 65.0 6.1 67.5 2.2 70.0 1.1 72.5 1.1 75.0 0.6 77.5 0.6 80.0 0.6 82.5 0.6 85.0 0.6 87.5 0.6 90.0 0.0 # IESNA91 # [TEST] LSI 12232 # [DATE] 09/11/95 # [MANUFAC] RUUD LIGHTING # [LUMCAT] RT18F-26 # [LUMINAIRE] BAFFLE W/REFLECTOR # [LAMP] 26W FL # TILT=NONE # Bulbs: 1, 1800 lm each # Number of measured angles: 37 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous opening diameter (and height?): 0.470 ( 0.000 ) # Ballast factor: 1, Input power: 27 W # Source file: rt18f-26.ies # Luminaire flux = 860 lm, # 47.8 % of the bulb flux # between 75 and 90: 0.1 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 0.6 cd / 1000 lm , 0.1 % of the luminaire flux # 90deg and above: max 0.0 cd / 1000 lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 15 cd / 1000 lm, # 67.5 deg to < 76 deg: max 2 cd / 1000 lm, # maximum spec. lum. intensity 268 cd / 1000 lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 252 2.5 253 5.0 257 7.5 263 10.0 266 12.5 268 15.0 268 17.5 263 20.0 254 22.5 244 25.0 234 27.5 223 30.0 212 32.5 199 35.0 186 37.5 171 40.0 154 42.5 137 45.0 121 47.5 105 50.0 88.9 52.5 73.9 55.0 57.8 57.5 42.2 60.0 27.8 62.5 15.0 65.0 6.1 67.5 2.2 70.0 1.1 72.5 1.1 75.0 0.6 77.5 0.6 80.0 0.6 82.5 0.6 85.0 0.6 87.5 0.6 90.0 0.0