Illuminance plots of rt15fritr

(as computed by ies2tab from that IES photometry file)

spacing 5 plot single luminaire plot
In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). The right plot is for a single luminaire, unrotated.

illuminance scale

Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.

ies2tab text output:

   
       
# IESNA91
# [TEST] LSI 8443
# [DATE] 04/20/89
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] RT15FRITR
# [LUMINAIRE] FRESNEL W/INTERNAL REFLECTOR
# [LAMP] 13W FL
# TILT=NONE
# Bulbs: 1,    900 lm each
# Number of measured angles:  19 vertical,   1 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous openig width, length and height:   0.420   0.420   0.000
# Ballast factor: 1,  Input power:   18 W


# Source file: rt15fritr.ies
# Luminaire flux =   380 lm,
#                   42.2 % of the bulb flux
# between 75 and 90:  2.3 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max  10.0 cd/1000lm ,  0.6 % of the luminaire flux
# 90deg and above:  max   0.0 cd/1000lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max    34 cd/1000lm,
# 67.5 deg to <72.5 deg:   max    24 cd/1000lm,
# maximum spec. lum. intensity   174 cd/1000lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

  0.0   168
  5.0   169
 10.0   172
 15.0   174
 20.0   174
 25.0   170
 30.0   160
 35.0   143
 40.0   123
 45.0   101
 50.0  80.0
 55.0  62.2
 60.0  47.8
 65.0  34.4
 70.0  24.4
 75.0  16.7
 80.0  10.0
 85.0   4.4
 90.0   0.0

# IESNA91
# [TEST] LSI 8443
# [DATE] 04/20/89
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] RT15FRITR
# [LUMINAIRE] FRESNEL W/INTERNAL REFLECTOR
# [LAMP] 13W FL
# TILT=NONE
# Bulbs: 1,    900 lm each
# Number of measured angles:  19 vertical,   1 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous openig width, length and height:   0.420   0.420   0.000
# Ballast factor: 1,  Input power:   18 W


# Source file: rt15fritr.ies
# Luminaire flux =   380 lm,
#                   42.2 % of the bulb flux
# between 75 and 90:  2.3 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max  10.0 cd / 1000 lm ,  0.6 % of the luminaire flux
# 90deg and above:  max   0.0 cd / 1000 lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max    34 cd / 1000 lm,
# 67.5 deg to < 76  deg:   max    24 cd / 1000 lm,
# maximum spec. lum. intensity   174 cd / 1000 lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

  0.0   168
  5.0   169
 10.0   172
 15.0   174
 20.0   174
 25.0   170
 30.0   160
 35.0   143
 40.0   123
 45.0   101
 50.0  80.0
 55.0  62.2
 60.0  47.8
 65.0  34.4
 70.0  24.4
 75.0  16.7
 80.0  10.0
 85.0   4.4
 90.0   0.0