Illuminance plots of qv410cry

(as computed by ies2tab from that IES photometry file)

spacing 5 plot single luminaire plot
In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). The right plot is for a single luminaire, unrotated.

illuminance scale

Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.

ies2tab text output:

   
       
# IESNA91
# [TEST] ITL 37940
# [DATE] 04/17/91
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] QV410CRY
# [LUMINAIRE] 16" QUADRATE VERTICAL W/CRYSTAL LENS
# [LAMP] 100 WATT MH
# TILT=NONE
# Bulbs: 1,   8500 lm each
# Number of measured angles:  11 vertical,   5 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous openig width, length and height:   1.180   1.180   0.000
# Ballast factor: 1,  Input power:  125 W


# Source file: qv410cry.ies
# Luminaire flux =  4431 lm,
#                   52.1 % of the bulb flux
# between 75 and 90:  5.3 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max  10.4 cd/1000lm ,  0.0 % of the luminaire flux
# 90deg and above:  max   0.0 cd/1000lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max    95 cd/1000lm,
# 67.5 deg to <72.5 deg:   max   -12 cd/1000lm,
# maximum spec. lum. intensity   130 cd/1000lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

#  H:   0.0  22.5  45.0  67.5  90.0
#V:  
  0.0  89.6  89.6  89.6  89.6  89.6
  5.0  93.8  93.5  93.8  93.4  93.5
 15.0   110   110   110   112   112
 25.0   114   116   119   121   123
 35.0   120   124   127   128   128
 45.0   121   124   130   128   127
 55.0   113   114   119   116   116
 65.0  93.1  90.2  91.6  90.7  94.6
 75.0  53.4  51.1  50.4  50.5  54.5
 85.0  10.4   9.8   9.2   8.8   9.5
 90.0   0.0   0.0   0.0   0.0   0.0

# IESNA91
# [TEST] ITL 37940
# [DATE] 04/17/91
# [MANUFAC] RUUD LIGHTING
# [LUMCAT] QV410CRY
# [LUMINAIRE] 16" QUADRATE VERTICAL W/CRYSTAL LENS
# [LAMP] 100 WATT MH
# TILT=NONE
# Bulbs: 1,   8500 lm each
# Number of measured angles:  11 vertical,   5 horizontal ones
# Photometric type: 1,  Units type: 1
# Luminous openig width, length and height:   1.180   1.180   0.000
# Ballast factor: 1,  Input power:  125 W


# Source file: qv410cry.ies
# Luminaire flux =  4431 lm,
#                   52.1 % of the bulb flux
# between 75 and 90:  5.3 % of the luminaire flux
#  - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above:  max  10.4 cd / 1000 lm ,  0.0 % of the luminaire flux
# 90deg and above:  max   0.0 cd / 1000 lm ,  0.0 % of the luminaire flux
# CutOff Type: Full_CutOff    

# 62.5 deg to <67.5 deg:   max    95 cd / 1000 lm,
# 67.5 deg to < 76  deg:   max    54 cd / 1000 lm,
# maximum spec. lum. intensity   130 cd / 1000 lm

# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):

#  H:   0.0  22.5  45.0  67.5  90.0
#V:  
  0.0  89.6  89.6  89.6  89.6  89.6
  5.0  93.8  93.5  93.8  93.4  93.5
 15.0   110   110   110   112   112
 25.0   114   116   119   121   123
 35.0   120   124   127   128   128
 45.0   121   124   130   128   127
 55.0   113   114   119   116   116
 65.0  93.1  90.2  91.6  90.7  94.6
 75.0  53.4  51.1  50.4  50.5  54.5
 85.0  10.4   9.8   9.2   8.8   9.5
 90.0   0.0   0.0   0.0   0.0   0.0