# An overview of fully shielded luminaires from RUUD
# SORTED on maximum specifix luminous intensity at 62.5 to < 67.5 degrees
# 3 max cd/klm at 80 degrees
# 5 max cd/klm at 62.5 to < 67.5 degrees
# 6 max cd/klm at 67.5 to < 76 degrees
# 7 max cd/klm in any direction
# 1 flux out from the luminaire relative to lamp flux
# and relative to all light emitted from the luminaire:
# 2 % at 75 to 90 degrees from nadir
# 4 % at 80 degrees and above
#FiOut 75-90 >= 80degrees 65 70 abs. filename
# % % cd/klm % Out maxima cd/klm
100.0 4.0 148.4 1.1 965 865 965 LYDACB04C
100.0 5.9 414.3 1.7 897 970 970 LYSTMB12C
100.0 5.9 360.5 1.9 780 937 937 LYDTMB04C
100.0 1.9 43.6 0.5 733 697 774 LYDTSB04C
100.0 4.5 154.4 1.2 644 641 644 LYSAC12C
100.0 6.9 248.9 2.2 601 652 652 LYDPRB04C
100.0 5.4 178.9 1.5 595 670 670 LYDAC04C
100.0 5.7 310.9 1.6 577 658 658 LYDTM06C
100.0 5.7 331.6 1.6 572 671 671 LYSTM12C
100.0 2.7 44.6 0.5 510 531 565 LYDTS04C
100.0 3.0 57.2 0.5 492 520 548 LYSTS12C
100.0 8.2 237.4 2.5 471 468 510 LYDPR04C
100.0 7.8 212.7 2.4 457 462 488 LYSPR12C
100.0 8.7 80.7 2.0 403 376 403 LYSQVM12C
100.0 13.4 131.3 3.9 385 374 385 LYDQVM04C
100.0 0.7 8.5 0.2 361 214 445 LYSQVS12C
100.0 0.2 2.5 0.1 121 13 393 LYSFS12C
100.0 0.0 0.5 0.0 13 5 1685 LYS4006C
100.0 0.1 0.6 0.0 10 6 9418 LYS1506C
99.9 0.1 0.7 0.0 9 6 3834 LYS2506C