Illuminance plots of Thema_T2-MTC-LYRE-PP-RETROLED-ROAD-NRN_36_DS-WW_70_6100_WW_LED

(as computed by ies2tab from that IES photometry file)

spacing 5 plot single luminaire plot
In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). The right plot is for a single luminaire, unrotated.

illuminance scale

Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.

ies2tab text output:

   
       
# [MANUFAC]   INDAL
# [TEST]      IN120330A5
# [LUMINAIRE] T2-MTC-LYRE-PP-RETROLED-ROAD
# [LUMCAT]    Thema 
# [DATE]      26/04/2012/02/04/2012/30/03/2012 / FAUVIN
# down given: 97%
# out given: 73.1%
# tilt:  0.0
# [LAMP]      36 DS-WW 70 6100 WW LED
# Bulbs: 1,   6100 lm each
Not rising horizontal angles.