In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91 # [TEST] LSI 8015 # [DATE] 01/19/89 # [MANUFAC] RUUD LIGHTING # [LUMCAT] AA540 # [LUMINAIRE] 16" RECESSED DOWNLIGHT (MEDIUM DISTRIBUTION) # [LAMP] 250 WATT HPS # TILT=NONE # Bulbs: 1, 27500 lm each # Number of measured angles: 37 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous openig width, length and height: 1.370 1.370 0.000 # Ballast factor: 1, Input power: 300 W # Source file: aa525.ies # Luminaire flux = 18854 lm, # 68.6 % of the bulb flux # between 75 and 90: 1.0 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 5.1 cd/1000lm , 0.3 % of the luminaire flux # 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 51 cd/1000lm, # 67.5 deg to <72.5 deg: max 27 cd/1000lm, # maximum spec. lum. intensity 239 cd/1000lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 206 5.0 177 10.0 156 15.0 168 20.0 189 25.0 208 30.0 220 35.0 231 40.0 239 45.0 237 50.0 208 55.0 148 60.0 87.6 65.0 51.0 70.0 26.5 75.0 12.2 80.0 5.1 85.0 1.8 90.0 0.0 95.0 0.0 100.0 0.0 105.0 0.0 110.0 0.0 115.0 0.0 120.0 0.0 125.0 0.0 130.0 0.0 135.0 0.0 140.0 0.0 145.0 0.0 150.0 0.0 155.0 0.0 160.0 0.0 165.0 0.0 170.0 0.0 175.0 0.0 180.0 0.0 # IESNA91 # [TEST] LSI 8015 # [DATE] 01/19/89 # [MANUFAC] RUUD LIGHTING # [LUMCAT] AA540 # [LUMINAIRE] 16" RECESSED DOWNLIGHT (MEDIUM DISTRIBUTION) # [LAMP] 250 WATT HPS # TILT=NONE # Bulbs: 1, 27500 lm each # Number of measured angles: 37 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous openig width, length and height: 1.370 1.370 0.000 # Ballast factor: 1, Input power: 300 W # Source file: aa525.ies # Luminaire flux = 18854 lm, # 68.6 % of the bulb flux # between 75 and 90: 1.0 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 5.1 cd / 1000 lm , 0.3 % of the luminaire flux # 90deg and above: max 0.0 cd / 1000 lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 51 cd / 1000 lm, # 67.5 deg to < 76 deg: max 27 cd / 1000 lm, # maximum spec. lum. intensity 239 cd / 1000 lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 206 5.0 177 10.0 156 15.0 168 20.0 189 25.0 208 30.0 220 35.0 231 40.0 239 45.0 237 50.0 208 55.0 148 60.0 87.6 65.0 51.0 70.0 26.5 75.0 12.2 80.0 5.1 85.0 1.8 90.0 0.0 95.0 0.0 100.0 0.0 105.0 0.0 110.0 0.0 115.0 0.0 120.0 0.0 125.0 0.0 130.0 0.0 135.0 0.0 140.0 0.0 145.0 0.0 150.0 0.0 155.0 0.0 160.0 0.0 165.0 0.0 170.0 0.0 175.0 0.0 180.0 0.0