| In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91
# [TEST] GE 8359
# [MANUFAC] GE Lighting Systems - Hendersonville NC USA
# [LUMCAT] (not specific to a single catalog number)
# [LUMINAIRE] GE UNIGLOW 150 ENCL
# [LAMP] MET 175C
# [OTHER] Distribution: SC 1.9
# [MORE] Socket Pos: D
# [MORE] Comments: - -
# [MORE] Revision No: 0 Rev Date: 910917 Test Date: 91011103
# [MORE] Reflector: 35-440011-01 Refractor: FLAT GLASS
# TILT=NONE
# Bulbs: 1, 10000 lm each
# Number of measured angles: 37 vertical, 1 horizontal ones
# Photometric type: 1, Units type: 1
# Luminous opening diameter (and height?): 1.500 ( 0.000 )
# Ballast factor: 1, Input power: 0 W
# Source file: ies/ge8359.ies
# Luminaire flux = 7678 lm,
# 76.8 % of the bulb flux
# between 75 and 90: 0.9 % of the luminaire flux
# - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above: max 3.4 cd/1000lm , 0.2 % of the luminaire flux
# 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux
# CutOff Type: Full_CutOff
# 62.5 deg to <67.5 deg: max 107 cd/1000lm,
# 67.5 deg to <72.5 deg: max 58 cd/1000lm,
# maximum spec. lum. intensity 245 cd/1000lm
# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):
0.0 180
5.0 179
10.0 179
15.0 178
20.0 176
25.0 174
30.0 182
35.0 201
40.0 226
45.0 245
50.0 236
55.0 198
60.0 153
65.0 107
70.0 57.5
75.0 18.2
80.0 3.4
85.0 0.7
90.0 0.0
95.0 0.0
100.0 0.0
105.0 0.0
110.0 0.0
115.0 0.0
120.0 0.0
125.0 0.0
130.0 0.0
135.0 0.0
140.0 0.0
145.0 0.0
150.0 0.0
155.0 0.0
160.0 0.0
165.0 0.0
170.0 0.0
175.0 0.0
180.0 0.0