| In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91
# [TEST] GE 8358
# [MANUFAC] GE Lighting Systems - Hendersonville NC USA
# [LUMCAT] (not specific to a single catalog number)
# [LUMINAIRE] GE UNIGLOW 150 ENCL
# [LAMP] MET 175
# [OTHER] Distribution: SC 1.7
# [MORE] Socket Pos: D
# [MORE] Comments: - -
# [MORE] Revision No: 0 Rev Date: 910917 Test Date: 91011102
# [MORE] Reflector: 35-440011-01 Refractor: FLAT GLASS
# TILT=NONE
# Bulbs: 1, 10000 lm each
# Number of measured angles: 37 vertical, 1 horizontal ones
# Photometric type: 1, Units type: 1
# Luminous opening diameter (and height?): 1.500 ( 0.000 )
# Ballast factor: 1, Input power: 0 W
# Source file: ies/ge8358.ies
# Luminaire flux = 7745 lm,
# 77.5 % of the bulb flux
# between 75 and 90: 0.3 % of the luminaire flux
# - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above: max 0.8 cd/1000lm , 0.0 % of the luminaire flux
# 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux
# CutOff Type: Full_CutOff
# 62.5 deg to <67.5 deg: max 83 cd/1000lm,
# 67.5 deg to <72.5 deg: max 34 cd/1000lm,
# maximum spec. lum. intensity 276 cd/1000lm
# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):
0.0 228
5.0 224
10.0 236
15.0 238
20.0 205
25.0 182
30.0 201
35.0 237
40.0 268
45.0 276
50.0 232
55.0 169
60.0 126
65.0 82.7
70.0 33.6
75.0 5.9
80.0 0.8
85.0 0.0
90.0 0.0
95.0 0.0
100.0 0.0
105.0 0.0
110.0 0.0
115.0 0.0
120.0 0.0
125.0 0.0
130.0 0.0
135.0 0.0
140.0 0.0
145.0 0.0
150.0 0.0
155.0 0.0
160.0 0.0
165.0 0.0
170.0 0.0
175.0 0.0
180.0 0.0