| In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91
# [TEST] GE 8176
# [MANUFAC] GE Lighting Systems - Hendersonville NC USA
# [LUMCAT] (not specific to a single catalog number)
# [LUMINAIRE] GE UNIGLOW 400/1000 ENCL
# [LAMP] HPS 750
# [OTHER] Distribution: SC 0.9
# [MORE] Socket Pos: H
# [MORE] Comments: 22IN -
# [MORE] Revision No: 0 Rev Date: 901119 Test Date: 90043005
# [MORE] Reflector: 35-232071-01 Refractor: FLAT GLASS
# TILT=NONE
# Bulbs: 1, 10000 lm each
# Number of measured angles: 37 vertical, 1 horizontal ones
# Photometric type: 1, Units type: 1
# Luminous opening diameter (and height?): 1.500 ( 0.000 )
# Ballast factor: 1, Input power: 0 W
# Source file: ies/ge8176.ies
# Luminaire flux = 8167 lm,
# 81.7 % of the bulb flux
# between 75 and 90: 0.0 % of the luminaire flux
# - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux
# 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux
# CutOff Type: Full_CutOff
# 62.5 deg to <67.5 deg: max 12 cd/1000lm,
# 67.5 deg to <72.5 deg: max 2 cd/1000lm,
# maximum spec. lum. intensity 635 cd/1000lm
# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):
0.0 558
5.0 635
10.0 615
15.0 534
20.0 440
25.0 375
30.0 326
35.0 279
40.0 237
45.0 202
50.0 151
55.0 104
60.0 48.9
65.0 12.4
70.0 2.2
75.0 0.1
80.0 0.0
85.0 0.0
90.0 0.0
95.0 0.0
100.0 0.0
105.0 0.0
110.0 0.0
115.0 0.0
120.0 0.0
125.0 0.0
130.0 0.0
135.0 0.0
140.0 0.0
145.0 0.0
150.0 0.0
155.0 0.0
160.0 0.0
165.0 0.0
170.0 0.0
175.0 0.0
180.0 0.0