In left plots, specific illuminances by a continuous row of luminaires spaced 5 and 6 heights are shown in their left halves (right half concerns a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA: LM-63-1995 # [TEST] 763052 # [DATE] 2/10/84 # [MANUFAC] COOPER LIGHTING # [LUMCAT] EGL91SXX66 # [LUMINAIRE] 1000W HPS 6H X 6V FLOOD # [LAMP] 1000W HPS CL E-25 # [_REFLECTOR] SPUN ALUMINUM # [_REFRACTOR] CLEAR FLAT GLASS # [_SOCKET POSITION] AXIAL # [_LAMP LUMENS] 140000 # TILT=NONE # Bulbs: 1, 140000 lm each # Number of measured angles: 46 vertical, 1 horizontal ones # Photometric type: 1, Units type: 1 # Luminous opening diameter (and height?): 1.830 ( 1.750 ) # Ballast factor: 1, Input power: 1000 W # Source file: egl91s66.ies # Luminaire flux = 68565 lm, # 49.0 % of the bulb flux # between 75 and 90: 0.7 % of the luminaire flux # - this part causes just GLARE in case of road lighting and similar purposes # 80deg and above: max 2.4 cd / 1000 lm , 0.4 % of the luminaire flux # 90deg and above: max 0.0 cd / 1000 lm , 0.0 % of the luminaire flux # CutOff Type: Full_CutOff # 62.5 deg to <67.5 deg: max 15 cd / 1000 lm, # 67.5 deg to < 76 deg: max 7 cd / 1000 lm, # maximum spec. lum. intensity 584 cd / 1000 lm # The following table gives luminous intensities which would be produced # using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm): 0.0 584 2.0 582 4.0 557 6.0 521 8.0 481 10.0 443 12.0 404 14.0 360 16.0 329 18.0 300 20.0 274 22.0 252 24.0 233 26.0 215 28.0 199 30.0 184 32.0 171 34.0 161 36.0 152 38.0 143 40.0 134 42.0 123 44.0 112 46.0 99.2 48.0 86.7 50.0 75.0 52.0 63.5 54.0 53.2 56.0 43.5 58.0 35.2 60.0 27.7 62.0 20.9 64.0 15.4 66.0 10.4 68.0 6.7 70.0 5.2 72.0 4.0 74.0 3.4 76.0 3.0 78.0 2.5 80.0 2.4 82.0 2.4 84.0 2.4 86.0 2.4 88.0 2.4 90.0 0.0