| In the left half of the left plot, specific illuminance by a continuous row of luminaires spaced 5 heights is shown (right half is for a single luminaire). | The right plot is for a single luminaire, unrotated. |
Values below the scale are illuminance / 1 lx. This is for (unrealistic) “unit” case that luminaires would have lamps producing 1 klm only, would be point-like and just 1 m over the terrain.
# IESNA91
# [TEST] GE 8360
# [MANUFAC] GE Lighting Systems - Hendersonville NC USA
# [LUMCAT] (not specific to a single catalog number)
# [LUMINAIRE] GE UNIGLOW 150 OPEN
# [LAMP] HPS 70-150
# [OTHER] Distribution: SC 1.8
# [MORE] Socket Pos: D
# [MORE] Comments: - -
# [MORE] Revision No: 0 Rev Date: 910917 Test Date: 91021201
# [MORE] Reflector: 35-440011-01 Refractor: -
# TILT=NONE
# Bulbs: 1, 10000 lm each
# Number of measured angles: 37 vertical, 1 horizontal ones
# Photometric type: 1, Units type: 1
# Luminous opening diameter (and height?): 1.500 ( 0.000 )
# Ballast factor: 1, Input power: 0 W
# Source file: ies/ge8360.ies
# Luminaire flux = 8754 lm,
# 87.5 % of the bulb flux
# between 75 and 90: 0.2 % of the luminaire flux
# - this part causes just GLARE in case of road lighting and similar purposes
# 80deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux
# 90deg and above: max 0.0 cd/1000lm , 0.0 % of the luminaire flux
# CutOff Type: Full_CutOff
# 62.5 deg to <67.5 deg: max 99 cd/1000lm,
# 67.5 deg to <72.5 deg: max 42 cd/1000lm,
# maximum spec. lum. intensity 316 cd/1000lm
# The following table gives luminous intensities which would be produced
# using a hypothetic bulb giving a luminous flux of 1000 lm (i.e., cd/klm):
0.0 226
5.0 210
10.0 224
15.0 233
20.0 201
25.0 184
30.0 217
35.0 269
40.0 308
45.0 316
50.0 276
55.0 207
60.0 150
65.0 98.9
70.0 42.2
75.0 7.4
80.0 0.0
85.0 0.0
90.0 0.0
95.0 0.0
100.0 0.0
105.0 0.0
110.0 0.0
115.0 0.0
120.0 0.0
125.0 0.0
130.0 0.0
135.0 0.0
140.0 0.0
145.0 0.0
150.0 0.0
155.0 0.0
160.0 0.0
165.0 0.0
170.0 0.0
175.0 0.0
180.0 0.0